IEC 60068-2-39, IEC 60068-2-40 and IEC 60068-2-41 address different aspects of combined environmental testing under reduced air pressure. While IEC 60068-2-39:2015 covers combined temperature or temperature and humidity with low air pressure, the original IEC 60068-2-40 and IEC 60068-2-41 methods focus on combined cold and low-pressure testing and dry heat and low-pressure testing, respectively. 


This engineering guide compares their technical scopes, publication status, environmental test conditions and equipment requirements, helping engineers, laboratory managers and procurement teams identify the appropriate temperature-altitude or temperature-humidity-altitude testing system for their applications.


Understanding the Differences Between IEC 60068-2-39, IEC 60068-2-40 and IEC 60068-2-41

Environmental testing becomes more challenging when products must operate or be stored under multiple environmental conditions simultaneously.

For aerospace electronics, aviation components, automotive electronics and other reliability-critical equipment, exposure to low air pressure combined with extreme temperatures can introduce failure mechanisms that may not be identified through conventional temperature or altitude testing alone.


Three IEC 60068 test references are particularly relevant to this subject:

• IEC 60068-2-39: Combined temperature or temperature and humidity with low air pressure testing.

• IEC 60068-2-40: Test Z/AM – Combined cold/low air pressure testing.

• IEC 60068-2-41: Test Z/BM – Combined dry heat/low air pressure testing.

Although these standards address related environmental conditions, they have different technical scopes and publication histories.

For engineers, laboratory managers and equipment procurement teams, understanding these differences is essential before defining a test procedure or purchasing a combined environmental test chamber.

The key distinction is the environmental combination being evaluated: combined temperature and pressure, cold and pressure, or dry heat and pressure.


IEC 60068-2-39: Combined Temperature or Temperature and Humidity With Low Air Pressure

IEC 60068-2-39:2015 specifies test methods and guidance for evaluating equipment and components under combined temperature, or temperature and humidity, with low air pressure.

Its objective is to investigate how combined environmental conditions affect electrical, mechanical and other physical characteristics of a specimen.

Unlike a test that evaluates temperature or altitude independently, this method considers the interaction between environmental parameters.

Depending on the relevant product specification, the test conditions can include:

• Low temperature

• Elevated temperature

• Controlled humidity

• Reduced air pressure

• Defined exposure duration

• Specified specimen operating conditions

The 2015 second edition replaced the original 1976 edition and introduced updated preferred severities, including combined temperature, humidity and low air pressure conditions.

This makes IEC 60068-2-39 particularly relevant when a product must be evaluated under multiple environmental stresses simultaneously.


Typical applications include:

• Aerospace electronic equipment

• Aviation control systems

• Electronic components

• Communication equipment

• Sensors and instrumentation

• Equipment designed for high-altitude environments

Engineering Considerations

The most important consideration is that temperature, humidity and pressure must be controlled as coordinated test parameters.

For example, reducing chamber pressure can influence moisture behavior, heat transfer and the thermal response of the specimen.


Engineers should therefore evaluate:

  • Required temperature range.

  • Required low-pressure conditions.

  • Humidity control requirements.

  • Specimen thermal stability.

  • Exposure duration.

  • Functional monitoring requirements.

IEC 60068-2-39 also emphasizes that exposure duration is measured after the specimen has reached the required temperature stability under low-pressure conditions.

This is an important distinction when designing test sequences and interpreting test results.


IEC 60068-2-40: Test Z/AM – Combined Cold and Low Air Pressure

IEC 60068-2-40 addresses the combined effects of low temperature and reduced air pressure.

Its original purpose was to determine whether components, equipment and other products could be stored or operated under simultaneous cold and low-pressure conditions.

The test is particularly relevant when the product is expected to experience cold environments at high altitude or in other reduced-pressure applications.

The two primary environmental parameters are:

• Low temperature

• Low air pressure

The method considers both heat-dissipating and non-heat-dissipating specimens.

This distinction is important because a powered specimen may generate internal heat, changing its actual thermal behavior during the test.

Engineering Considerations


When planning a combined cold and low-pressure test, engineers should consider:

• Minimum required temperature

• Target chamber pressure

• Pressure reduction rate

• Temperature stabilization

• Specimen heat dissipation

• Operating or storage condition

• Exposure duration

• Recovery and post-test inspection

A critical point is that the specimen's internal temperature may differ from the chamber air temperature.

For heat-dissipating products, specimen mounting, power consumption and heat transfer conditions can influence the test outcome.

Therefore, chamber performance should be evaluated using the actual specimen configuration rather than relying exclusively on an empty-chamber specification.


Typical Applications

• Aircraft electronic equipment

• Aerospace instrumentation

• High-altitude electronic systems

• Aviation communication components

• Outdoor electronic equipment

• Components exposed to cold and reduced-pressure environments

Standard status note: The IEC 60068-2-40:1976 publication is listed as withdrawn in the IEC catalogue, with a withdrawal date of November 21, 2018. Engineers should verify the applicable contractual specification and current national or industry adoption before citing this document as a compliance requirement.


IEC 60068-2-41: Test Z/BM – Combined Dry Heat and Low Air Pressure

IEC 60068-2-41 addresses the combined effects of dry heat and low air pressure.

Its original purpose was to determine the ability of components, equipment and other products to withstand simultaneous exposure to elevated temperature and reduced atmospheric pressure.

Compared with IEC 60068-2-40, the main difference is the temperature condition.

• IEC 60068-2-40 focuses on combined cold and low air pressure.

• IEC 60068-2-41 focuses on combined dry heat and low air pressure.

The method considers both heat-dissipating and non-heat-dissipating specimens.

This is particularly important when evaluating products that generate heat during operation.


Engineering Considerations

For combined dry heat and low-pressure testing, the test system must maintain the required elevated temperature while controlling the specified pressure condition.

Important parameters include:

• Maximum test temperature

• Target low air pressure

• Temperature uniformity

• Specimen heat dissipation

• Pressure stability

• Exposure duration

• Operating conditions

• Temperature recovery

Reduced air pressure changes the heat-transfer characteristics of the surrounding environment.

Consequently, a specimen that performs normally under atmospheric pressure may exhibit different thermal behavior under reduced pressure.

This can be particularly relevant for electronic equipment, power components and aerospace systems.


Typical Applications

• Aerospace electronic assemblies

• High-altitude equipment

• Electronic control units

• Heat-generating electrical components

• Aviation instrumentation

• Components designed for elevated-temperature environments

Standard status note: IEC 60068-2-41:1976 is also listed as withdrawn in the IEC catalogue, with a withdrawal date of November 21, 2018. Its original technical scope remains useful for understanding historical Test Z/BM requirements, but current compliance must be determined from the applicable specification and recognized replacement or adopted document.


IEC 60068-2-39 vs IEC 60068-2-40 vs IEC 60068-2-41: Technical Comparison

The following comparison summarizes the primary differences.

Evaluation Factor

IEC 60068-2-39

IEC 60068-2-40

IEC 60068-2-41

Main Test Scope

Combined temperature or temperature/humidity with low air pressure

Combined cold and low air pressure

Combined dry heat and low air pressure

Temperature Condition

Cold or elevated temperature

Low temperature

Elevated temperature

Humidity

Included in the 2015 edition

Not the defining test condition

Not the defining test condition

Low Air Pressure

Yes

Yes

Yes

Heat-Dissipating Specimens

Relevant to specimen configuration

Covered

Covered

Main Engineering Focus

Combined environmental effects

Cold and altitude-related effects

Heat and altitude-related effects

IEC Publication

2015, Edition 2

1976, Edition 1

1976, Edition 1

IEC Catalogue Status

Published

Withdrawn

Withdrawn

Important: These three documents should not be treated as interchangeable standards. Their technical scopes, editions and publication statuses must be checked against the actual product specification.


How Do Combined Temperature and Low Pressure Affect Product Reliability?

Testing temperature and low pressure simultaneously can reveal potential problems that may not appear when these conditions are evaluated separately.

The interaction between temperature and pressure can influence several physical and electrical characteristics.

Heat Transfer and Thermal Stability

At reduced pressure, gas density decreases, which can change convective heat transfer.

For heat-generating products, this can affect internal temperature distribution and thermal stability.

The actual response depends on specimen geometry, material properties, heat generation and the surrounding test conditions.


Electrical Insulation and High-Voltage Performance

Reduced air pressure can affect the electrical insulation characteristics of gas-filled spaces.

Depending on the design and operating voltage, products may experience changes in discharge behavior or insulation performance.

For high-voltage components, the applicable electrical test requirements should be evaluated separately rather than assuming that a low-pressure environmental test alone establishes insulation compliance.


Mechanical and Material Behavior

Temperature changes can affect material dimensions, mechanical interfaces and sealing performance.

Under combined environmental conditions, engineers may need to investigate:

• Seal deformation

• Material expansion and contraction

• Mechanical connection stability

• Housing integrity

• Component mounting performance


Functional Performance

Electronic systems may behave differently under reduced pressure and temperature extremes.

Functional monitoring during exposure can help identify intermittent faults, abnormal operating conditions and performance degradation.

The test specification should clearly define whether the specimen is switched on, switched off or operated under a specified duty cycle.


What Equipment Is Required for IEC 60068 Combined Environmental Testing?

A conventional temperature chamber or altitude chamber may not be sufficient when the test requires multiple environmental parameters to be controlled simultaneously.

Depending on the required test conditions, laboratories may need a customized temperature and low-pressure test system.

Option 1: Temperature and Low-Pressure Test Chamber

This configuration is intended for applications requiring controlled temperature and reduced air pressure.

Typical engineering requirements include:

• Specified temperature range

• Controlled pressure range

• Vacuum pumping system

• Pressure measurement and control

• Temperature regulation

• Programmable test sequences

• Data monitoring

This type of system may be suitable for combined cold/low-pressure or dry-heat/low-pressure applications.


Option 2: Temperature-Humidity-Altitude Test Chamber

For test programs requiring temperature, humidity and reduced atmospheric pressure simultaneously, a more integrated environmental simulation system may be required.

The configuration may include:

• Heating and cooling systems

• Humidity generation and control

• Vacuum pumping and pressure regulation

• Temperature and humidity sensors

• Pressure monitoring

• Programmable control systems

• Test data recording

The system must be designed to maintain the required environmental conditions without allowing one parameter to compromise another.


Option 3: Customized Combined Environmental Testing System

For laboratories supporting multiple product categories, a customized system may offer greater flexibility.

The design can be determined by:

• Required temperature extremes

• Pressure range

• Humidity range

• Working chamber volume

• Specimen dimensions

• Heat dissipation

• Number of specimens

• Electrical feedthrough requirements

• Functional monitoring

• Test sequence

The most appropriate configuration should be selected from the complete test specification, not simply from the equipment name.


What Should Engineers Specify Before Purchasing a Combined Test Chamber?

One of the most common procurement mistakes is specifying only the temperature range and maximum vacuum capability.

A technically complete RFQ should define the actual operating conditions.

Temperature Requirements

  • Minimum temperature

  • Maximum temperature

  • Temperature fluctuation

  • Temperature uniformity

  • Heating and cooling performance

  • Stabilization requirements


Pressure Requirements

  • Required absolute pressure

  • Equivalent altitude, if applicable

  • Pressure reduction rate

  • Pressure recovery rate

  • Pressure stability

  • Measurement accuracy

Always specify absolute pressure in the RFQ. Altitude can be included as a supplementary reference, but it should not replace the actual pressure requirement.


Humidity Requirements

If humidity is required, define:

  • Relative humidity range

  • Required temperature and humidity combinations

  • Humidity stability

  • Operating pressure range

  • Condensation prevention requirements

Humidity control under reduced pressure requires particular attention to the physical operating limits of the system.

Do not assume that a conventional temperature-humidity chamber can maintain its full humidity range under vacuum conditions.


DUT and Test Load

Provide:

  • Product dimensions

  • Product weight

  • Number of specimens

  • Heat dissipation

  • Electrical power requirements

  • Cable and feedthrough requirements

  • Fixture configuration


Validation and Documentation

Before accepting the equipment, clarify:

  • Factory Acceptance Test (FAT)

  • Site Acceptance Test (SAT)

  • Temperature measurement points

  • Pressure measurement and calibration

  • Humidity verification, if applicable

  • Data logging and export

  • Test program documentation

  • Operating and maintenance manuals

A clearly defined acceptance procedure makes it easier to compare quotations from different equipment manufacturers.


How to Select the Right Combined Environmental Test System

The selection process should start with the required environmental combination.

For cold plus low pressure: Evaluate a temperature and altitude test chamber capable of maintaining the required low-temperature and pressure conditions.

For dry heat plus low pressure: Evaluate a high-temperature and low-pressure system with sufficient thermal capacity and pressure stability.

For temperature or temperature-humidity plus low pressure: Evaluate a more comprehensive combined environmental test system based on IEC 60068-2-39:2015 and the relevant product specification.

For laboratories handling multiple standards, it may be more practical to specify a configurable system that supports different environmental profiles.

However, flexibility should never be assumed to mean that all combinations are technically achievable. Temperature, humidity and pressure operating limits must be verified for each required test condition.


How TestEQ Supports Combined Temperature and Low-Pressure Testing

TestEQ provides environmental test equipment and customized reliability testing systems for applications requiring controlled temperature, humidity and other environmental conditions.

For combined temperature and low-pressure applications, system design should begin with the customer's actual test requirements.

Key engineering considerations include:

• Required temperature and pressure ranges

• Humidity control requirements

• Working chamber dimensions

• Specimen heat dissipation

• Vacuum pumping capacity

• Pressure control and measurement

• Temperature stability

• Electrical feedthroughs

• Test program configuration

• Data acquisition and monitoring

Rather than selecting equipment based only on nominal temperature or vacuum specifications, TestEQ evaluates the complete environmental test profile to determine a suitable system configuration.

This approach is particularly relevant to aerospace, aviation electronics, communication equipment, semiconductor-related applications and other reliability testing laboratories.


Why Choose TestEQ for Combined Environmental Testing Systems?

Choosing a combined environmental test chamber requires more than checking temperature and pressure specifications. It requires an engineering partner who understands the interaction between environmental conditions, DUT characteristics and actual testing requirements.

TestEQ provides:

• Customized System Design: Environmental testing solutions configured around specific temperature, pressure, humidity and chamber volume requirements.

• Engineering Experience: More than 15 years of experience in environmental test equipment development and manufacturing.

• Integrated Testing Capabilities: Solutions covering temperature, humidity, low pressure, thermal vacuum and other combined environmental testing applications.

• Manufacturing and Technical Support: In-house manufacturing capabilities, system integration and technical support throughout equipment configuration and delivery.

• Quality and Verification: Quality management under ISO 9001, with equipment verification and calibration documentation available according to project requirements.

From individual environmental test chambers to customized reliability testing systems, TestEQ works with engineers, laboratories and procurement teams to develop equipment configurations aligned with their testing objectives.


Frequently Asked Questions: IEC 60068-2-39 vs IEC 60068-2-40 vs IEC 60068-2-41

1. What Is the Difference Between IEC 60068-2-39, IEC 60068-2-40 and IEC 60068-2-41?

IEC 60068-2-39:2015 covers combined temperature, or temperature and humidity, with low air pressure testing. IEC 60068-2-40:1976 originally addressed combined cold and low air pressure testing (Test Z/AM), while IEC 60068-2-41:1976 addressed combined dry heat and low air pressure testing (Test Z/BM).

The main difference is the environmental conditions evaluated. IEC 60068-2-39 has a broader combined environmental scope, whereas the two older methods focus on cold or dry heat under reduced pressure. Both 1976 publications are listed as withdrawn in the IEC catalogue.


2. Is IEC 60068-2-39 Still a Valid Standard for Combined Temperature and Low Pressure Testing?

IEC 60068-2-39:2015 is the second edition of the standard and is listed as a published IEC publication. It provides test methods and guidance for evaluating specimens under combined temperature, or temperature and humidity, with low air pressure.

Before using it for product qualification, engineers should verify the applicable edition, contractual requirements and any relevant national or industry adoption. The required test severities and acceptance criteria should also be defined in the product specification.


3. Are IEC 60068-2-40 and IEC 60068-2-41 Still Active?

No. The original IEC publications IEC 60068-2-40:1976 and IEC 60068-2-41:1976 are listed as withdrawn, with a withdrawal date of November 21, 2018.

IEC 60068-2-40 originally covered combined cold and low air pressure testing, while IEC 60068-2-41 covered combined dry heat and low air pressure testing. Engineers and procurement teams should confirm whether their project specifications reference these historical methods, an adopted national version or another applicable test requirement before selecting equipment.


4. What Type of Test Chamber Is Required for IEC 60068 Combined Temperature and Low Pressure Testing?

The required equipment depends on the environmental conditions specified in the test procedure.

A temperature and low-pressure test chamber may be suitable for combined temperature and pressure applications. When humidity is also required, a temperature-humidity-altitude test chamber or customized combined environmental testing system may be necessary.

The equipment should be evaluated based on its temperature range, absolute pressure range, humidity capability, working volume, DUT thermal load and environmental control stability. A conventional temperature chamber or altitude chamber alone may not satisfy a combined testing requirement.


5. Can One Temperature-Humidity-Altitude Chamber Perform IEC 60068-2-39, 2-40 and 2-41 Testing?

A customized temperature-humidity-altitude chamber may be configured to support multiple temperature and low-pressure test profiles. However, compatibility with all three methods should not be assumed.

The system must be evaluated against each required temperature range, pressure condition, humidity requirement, specimen configuration and operating mode. The withdrawn status of IEC 60068-2-40 and IEC 60068-2-41 must also be considered when defining the contractual test requirements.

For multi-standard laboratories, suppliers should provide a documented capability matrix showing which environmental combinations can be achieved and verified.


6. Why Is Absolute Pressure Important When Selecting an Altitude Test Chamber?

Absolute pressure is a critical parameter because it defines the actual pressure environment surrounding the test specimen.

Altitude values are useful for describing an equivalent atmospheric condition, but they should not replace the specified pressure requirement in an equipment RFQ.

Engineers should define the target absolute pressure, pressure reduction rate, pressure stability, recovery requirements and measurement accuracy. This allows manufacturers to select an appropriate vacuum pumping system, pressure control architecture and chamber configuration.


7. Can Humidity Be Controlled Under Low Air Pressure During Combined Environmental Testing?

Humidity control under reduced pressure is technically challenging because water vapor behavior, condensation conditions and heat transfer characteristics change with pressure and temperature.

Whether humidity can be controlled depends on the required pressure-temperature-humidity combination, chamber sealing, moisture management, control architecture and specimen conditions.

For IEC 60068-2-39 applications, engineers should specify the required humidity conditions together with the corresponding temperature and pressure values. Suppliers should verify that the requested operating combination is technically achievable rather than quoting a humidity range measured only at atmospheric pressure.


8. How Do Low Temperature and Low Pressure Affect Electronic Components and Aerospace Equipment?

Combined low-temperature and low-pressure exposure can affect thermal behavior, electrical insulation characteristics, material properties and product functionality.

Reduced pressure changes gas density and can reduce convective heat transfer, potentially affecting the operating temperature of heat-generating electronic components. Low temperature can also influence material contraction, mechanical interfaces, seals and electronic performance.

For aerospace electronics, sensors, communication equipment and control systems, combined environmental testing can help identify potential weaknesses that may not be detected through independent temperature or altitude testing.


9. What Parameters Should Engineers Include in an RFQ for a Temperature-Humidity-Altitude Test Chamber?

A technically complete RFQ should include the following information:

  • Minimum and maximum temperature.

  • Required absolute pressure range.

  • Equivalent altitude, if applicable.

  • Relative humidity range and required operating combinations.

  • Temperature and pressure transition rates.

  • Temperature uniformity and fluctuation requirements.

  • Pressure stability and measurement accuracy.

  • Chamber working dimensions.

  • DUT weight, quantity and thermal load.

  • Specimen operating or non-operating conditions.

  • Electrical feedthrough and monitoring requirements.

  • Applicable standards and editions.

  • FAT, SAT and calibration requirements.

Providing these details allows equipment manufacturers to evaluate the required system architecture and prepare more accurate technical proposals and quotations.


10. How Do I Choose Between an Altitude Chamber, Thermal Vacuum Chamber and Temperature-Humidity-Altitude Chamber?

The correct equipment depends on the required environmental simulation.

An Altitude Chamber primarily controls reduced atmospheric pressure and may include temperature regulation depending on its configuration.

A Thermal Vacuum Chamber is designed for controlled thermal and vacuum testing, particularly where low-pressure or high-vacuum conditions are required. It is commonly associated with aerospace and space-related applications.

A Temperature-Humidity-Altitude Chamber combines temperature, humidity and reduced atmospheric pressure control for applications requiring multiple environmental parameters simultaneously.

Before purchasing, engineers should compare the required pressure range, temperature range, humidity capability, specimen thermal load, working volume and test sequence. The chamber should be selected according to the actual test profile rather than its product category alone.


Internal Linking Modules


Standard Pages

Description: Learn how IEC 60068-2-13 defines low air pressure testing requirements, including pressure control, exposure duration, specimen conditions and altitude simulation for environmental reliability testing.

Description: Explore the IEC 60068 environmental testing series, covering temperature, humidity, low pressure, thermal cycling and other environmental stresses used in product reliability qualification.

Description: Understand RTCA DO-160 Section 4 requirements for evaluating aircraft equipment under temperature and reduced atmospheric pressure conditions, including altitude simulation and equipment selection.


Resources Pages

Description: Understand how temperature, humidity and reduced atmospheric pressure interact during combined environmental testing, including test profiles, engineering challenges and chamber configuration.

Description: Learn how to define thermal vacuum test requirements, including temperature range, vacuum level, thermal load, payload configuration and equipment acceptance criteria.

Description: Explore thermal vacuum testing procedures, environmental conditions and applications in aerospace and electronics, with practical guidance for selecting thermal vacuum equipment.


Products Pages

Description: Explore TestEQ altitude test chambers for low-pressure simulation, temperature-altitude testing and combined temperature-humidity-altitude applications, with customizable chamber configurations.

Description: Discover customized thermal vacuum testing systems for aerospace, satellite and electronic applications, combining controlled temperature profiles with high-vacuum environments.

Description: Explore environmental test chambers for controlled temperature, humidity and customized environmental simulation, supporting reliability validation across electronics, automotive, aerospace and industrial applications.


CTA

Need a Customized Temperature and Low Pressure Test Chamber?

Are you evaluating equipment for IEC 60068 combined temperature, humidity and low pressure testing?

Whether your application involves low-temperature altitude testing, high-temperature low-pressure testing, or combined temperature-humidity-altitude simulation, selecting the right chamber requires more than specifying a temperature range or vacuum level.

TestEQ provides customized environmental testing systems designed around your actual test conditions, DUT characteristics and laboratory requirements.


Discuss Your Testing Requirements with TestEQ

To help our engineering team evaluate your application, please provide:

  • Applicable IEC standard and edition

  • Required temperature range

  • Required absolute pressure range

  • Relative humidity requirements, if applicable

  • DUT dimensions and weight

  • Number of test specimens

  • Specimen heat dissipation and operating conditions

  • Required chamber working volume

Our engineering team can evaluate the required environmental control capabilities and recommend a suitable chamber configuration for your application.


"Request a Customized Test Chamber Solution →" 


Get a Technical Consultation | Request Chamber Configuration | Get a Quotation


TestEQ — Environmental Test Chambers & Reliability Testing Systems


Ask For A Quick Quote

We will contact you within 1 working day, please pay attention to the email with
the suffix "@test-eq.com".

We will contact you within 1 working day, please pay attention to the email with the suffix "@test-eq.com".

Company
Name*
Phone
E-Mail*
Nation
Message
By selecting the ‘I agree’ button, you consent to the processing of your personal data for marketing purposes and for the sending of commercial information by TESTEQ Company through telephone, e-mail, newsletters, text messages such as sms, chat and social networks.
I AGREE
By submitting your personal data, you declare that you have read the Privacy Policy of the website.

P.IVA: 91441900MAECQJHY37 Guangdong Test EQ Equipment Co., Ltd. | All Rights Reserved