Test EQ

All categories
Reliability Testing MIL-STD Walk-in Environmental Chambers
Technical Specifications

Temperature Range:-70°C to 100°C

Dew Point Temperature Range:7℃ to 87℃     

Extended Dew Point Conditions: -10℃     

Humidity Range:5%~98% RH   

Humidity Control:±2.5%RH     

Humidity Uniformity:±1.0 % RH

Noise test:≤ 68dB

Specifications
Serial
number
Capacity ( m³ )Description
1ModelWalk in
Environmental
Chamber
Tailored capacity: Servied capacity 1000m³/ 1600m³ /4500 etc
2Internal/External Dimension Customized
3   Temperature RangeLow Temperature: ( A: 25°C; B: 0°C; C: -20°C ; D: -40°C; E: -60°C ; F: -70°C)
High Temperature:  85°C  ( 100°C is optional)
4Dew Point Temperature Range7℃ to 87℃
5Extended Dew Point Conditions -10℃
6Humidity Range10%~98% RH
(5% ~98% RH,is a special optional condition,need Dehumidifier)
7Temperature Uniformity≦+/-2.0℃ at no load, constant state
8Temperature fluctuation≦+/-0.3℃ at no load, constant state
9Humidity fluctuation±3%RH at no load, constant state
10Humidity deviation≤ ±3%RH (humidity>75%RH);  ≤+5%RH(humiditys75%RH) at no load, constant state
11Cooling Time
(No-Load Condition)
25 →  -20℃Following tailored specific supporting 
25  →  -40℃
25  →  -60℃
12Heating Time (Min)
25  → +85℃
Following tailored specific supporting 
13PowerAC380V: 3phase 5 lines : 50/60HZ
14We possess the technical expertise to address integrated temperature-humidity control challenges
in low-pressure environments. Contact our sales team for scenario-specific solutions.


Product Features

Feature:

1.Integral structure, the inner wall special process rolling molding, the whole using TIG seamless welding, beautiful appearance; Door lock device adopts lever power opening mechanism.

2.The use of Chinese color LCD touch man-machine interface + high-performance programmable controller (PLC), with TESTEQ  test box special software, with automatic, intelligent, human control and other characteristics.

3.Control mode: constant operation mode, program operation mode.

4.Patented "static balance" technology, low temperature constant temperature season can be more than 30%.

5.Refrigeration compressor and key accessories are selected international and domestic well-known brands, long-term and reliable operation; Environmentally friendly refrigerant, in line with the requirements of international environmental protection conventions.

6.Configure RJ45 communication interface, remote control system (open data transmission protocol support Modbus/OPC).

7.Surface electrostatic powder spraying; Box color "TESTEQ White ", controller panel color "TESTEQ Blue ".

8.TESTEQ  patent cold well adsorption anti-condensation function (optional).


Meet standard(military-grade walk-in test chamber standards):

IEC 60068 Series - Environmental Testing International Standards 

Military walk-in test chambers must comply with the IEC 60068 basic environmental test procedures, where IEC 60068-2-1 (Cold Tests) and IEC 60068-2-2 (Dry Heat Tests) specify military temperature testing ranges from -65°C to +200°C, with typical test durations of 48-96 hours. 

MIL-STD-810 - US Military Environmental Engineering Standard  

Section 516.7 explicitly requires walk-in test chambers to have rapid temperature change capability (≥10°C/min) and pass 24 thermal shock cycles, with chamber temperature uniformity controlled within ±2°C. 

ISO 16750 - Road Vehicle Environmental Conditions Standard  

For military vehicle component testing, Chapter 4 specifies that walk-in test chambers should achieve -40°C to +120°C temperature cycling while simultaneously simulating 5000m altitude (54kPa) low-pressure environments. 

RTCA DO-160 - Airborne Equipment Environmental Tests  

 Temperature test chambers to maintain temperature gradients ≤3°C/m³ in the -55°C to +85°C range, while Chapter 24 (Sand/Dust Tests) specifies particle concentration at 10.6g/m³±7g/m³. 

DEF STAN 00-35 - UK Defense Standard  

Part 3 requires military test chambers to have triple-protection functions (anti-humidity/anti-salt spray/anti-mold), with mold tests lasting 28 days using test strains compliant with IEC 60068-2-10. 

NATO AECTP 300 - NATO Environmental Testing  

Clause 4.3.4 mandates walk-in test chambers to support -46°C to +71°C thermal shock testing with transition time ≤5 minutes and rate ≥15°C/min. 

IEC 60721 - Environmental Parameters Classification  

The standard categorizes military environments as Class 3K5 (shipboard), 4K5 (vehicle-mounted), etc., requiring test chambers to simulate combined temperature, humidity and vibration conditions. 

ASTM E595 - Material Outgassing Tests  

For aerospace materials, chambers must achieve vacuum levels of 5×10-5 Torr with quadrupole mass spectrometers to detect Total Mass Loss (TML) ≤1.0%. 

ISO 9022 - Optical Instrument Environmental Tests  

Part 12 specifies sand/dust test chambers must use ≥97% SiO2 content particles with adjustable wind speeds of 1-20m/s for military optical equipment testing. 

EN 60068-3-6 - Test Chamber Calibration Methods  

This European standard requires annual calibration of military test chambers, with sensor accuracy of ±0.1°C/±1%RH and 6-month calibration report validity.

Additional Options

Mainly used in aviation, aerospace, electronics, instrumentation, electrical products, materials, parts, complete machines and equipment for accelerated wet heat test, alternating wet heat test, constant wet test, It can also be used for high-low wet routine test, cold resistance test, low temperature storage, adaptability test under rapid temperature change or gradual change test of electrical and electronic products or for improving production efficiency. The performance and behavior can be analyzed and evaluated under the proposed environmental conditions in the test.


Videos
Related Products
  • Add: TESTEQ Science and Technology Park, No. 5, Wenzhou Road, Dongcheng Sub-district, Dongguan City, Guangdong Province, China

    Whatsapp(Phone): +8613310826672

    Tel: +86-0769-85914911

    Web: www.chamber-testing.com

    E-mail: Kris@test-eq.com

Ask For A Quick Quote

We will contact you within 1 working day, please pay attention to the email with
the suffix "@test-eq.com".

We will contact you within 1 working day, please pay attention to the email with the suffix "@test-eq.com".

Company
Name*
Phone
E-Mail*
Nation
Message
By selecting the ‘I agree’ button, you consent to the processing of your personal data for marketing purposes and for the sending of commercial information by TESTEQ Company through telephone, e-mail, newsletters, text messages such as sms, chat and social networks.
I AGREE
By submitting your personal data, you declare that you have read the Privacy Policy of the website.

P.IVA: 91441900MAECQJHY37 Guangdong TESTEQ Testing Equipment Co., LTD | All Rights Reserved