Test EQ

All categories
PRODUCTS
Walk-In Environmental Chamber for Industrial Temperature & Humidity Testing

Key Advantages

Large walk-in design for full product testing

Temperature Range:-70°C to 350°C

Dew Point Temperature Range:7℃ to 87℃     

Extended Dew Point Conditions: -10℃     

Humidity Range:5%~98% RH   

Humidity Control:±2.5%RH     

Humidity Uniformity:±1.0 % RH

Noise test:≤ 68dB

High uniformity and stability across a large area

Modular structure for custom room sizes

Efficient airflow and insulation system

Suitable for long-duration continuous testing


Key Specifications of Walk-In Environmental Chamber:


Serial
number
Capacity ( m³ )6.0 18.925.7
1ModelWalk in
Environmental
Chamber
EWTH7.8-20WEWTH11.7-20WEWTH15.6-20WEWTH21.6-20WEWTH29.4-20WEWTH44.1-20W
EWTH7.8-40WEWTH11.7-40WEWTH15.6-40WEWTH21.6-40WEWTH29.4-40WEWTH44.1-40W
EWTH7.8-65WEWTH11.7-65WEWTH15.6-65WEWTH21.6-65WEWTH29.4-65WEWTH44.1-65W
2Type A content volume7.811.715.621.629.444.1
3Type B content volume6.810.213.618.925.738.6
4Internal/External Dimension Customized
6   Temperature RangeLow Temperature: ( A: 25°C; B: 0°C; C: -20°C ; D: -40°C; E: -60°C ; F: -70°C)
High Temperature:  85°C  ( 350°C is optional)
7Humidity Range20%~98% RH
(5% ~98% RH,is a special optional condition,need Dehumidifier)
8Temperature Uniformity≦+/-2.0℃ 
9Temperature fluctuation≦+/-0.3℃ 
10Humidity fluctuation±3%RH  
11Humidity deviation≤ ±3%RH (humidity>75%RH);  ≤+5%RH(humiditys75%RH) at no load, constant state
12Cooling Time
(No-Load Condition)
25 →  -20℃45 Min60 Min75 Min40 Min50 Min70 Min
25  →  -40℃60 Min75 Min90 Min105 Min60 Min80 Min
25  →  -60℃100 Min120 Min140 Min105 Min135 Min160 Min
13Heating Time (Min)
25  → +85℃
455055506080
14PowerAC380V: 3phase 5 lines : 50/60HZ
15We possess the technical expertise to address integrated temperature-humidity control challenges
in low-pressure environments. Contact our sales team for scenario-specific solutions.


Opening:

The Walk-In Environmental Chamber is designed for large-scale environmental testing of complete products, assemblies, and systems. Unlike standard chambers, it provides a spacious test environment where operators can enter and conduct testing directly.

With a wide temperature range from -70°C to +150°C and optional humidity control, this chamber simulates real-world environmental conditions for automotive, aerospace, battery, and industrial applications.


What Is a Walk-In Environmental Chamber?

A Walk-In Environmental Chamber is a large-scale climate simulation system designed to test full-size products, assemblies, or batches under controlled temperature and humidity conditions.

Unlike benchtop or small test chambers, walk-in systems allow engineers to conduct full-scale reliability testing under real-world environmental stress conditions.

Typical applications include:

  • Automotive battery systems

  • Aerospace components

  • Energy storage systems

  • Electronics racks and modules


How Walk-In Environmental Chambers Work

A walk-in chamber integrates:

  • Refrigeration system (low-temperature control)

  • Heating system (high-temperature simulation)

  • Humidity generation system

  • Air circulation system (uniform distribution)

  • PLC / AI control system

Key principle:

Environmental conditions are uniformly distributed in a controlled sealed chamber to simulate real-world climate stress.


Structural Design:

The walk-in chamber features a modular panel structure, allowing flexible installation and expansion:

  • High-performance insulated panels

  • Anti-slip floor design

  • Airtight door with safety lock

  • window with heating function

  • Internal lighting system


 Designed for Large-Scale Testing

Walk-in chambers are ideal when:

  • Test samples are too large for standard chambers

  • Multiple products need to be tested simultaneously

  • Long-duration stability testing is required

  • Real operating conditions must be simulated


How to Choose a Walk-In Environmental Chamber

Selecting a walk-in environmental chamber requires evaluating several key factors:

1. Chamber size and test volume

Large products such as EV battery packs, vehicles, aerospace systems and industrial equipment require customized chamber dimensions.

2. Temperature range

Typical systems support -70°C to +150°C, while special applications may require wider ranges.

3. Humidity control capability

Humidity stability and uniformity are critical for climate reliability testing.

4. Testing standards

Engineers should consider IEC 60068, MIL-STD-810H, ISO 16750 and industry-specific requirements.

5. Future expansion

Modular walk-in designs allow additional zones, vibration integration or altitude simulation.


Walk-In Chamber vs Standard Chamber:

FeatureWalk-In ChamberStandard Chamber
Test SizeLarge systems/productsSmall components
Operator AccessHuman entryFront access
CapacitySeveral m³ to thousands m³Hundreds to thousands L
ApplicationEV pack, vehicle, aerospaceElectronics, components
CustomizationHighLimited


Industry Standards Compliance

Walk-In Environmental Chambers support international testing standards:

  • IEC 60068 Environmental Testing Standards

  • MIL-STD-810 Environmental Engineering Tests

  • MIL-STD-810H  Military & aerospace

  • ASTM D4332 Conditioning of Containers

  • ISO 16750 Road Vehicle Environmental Testing

  • JESD22  Semiconductor reliability

These standards ensure repeatable and globally recognized test results.


Why TestEQ Walk-In Environmental Chambers

TestEQ provides engineering-grade customization for industrial testing systems.

Key advantages:

  • Fully customized chamber size and configuration

  • High thermal uniformity control system

  • Energy-efficient refrigeration design

  • Stable long-term reliability performance

  • Engineering support for non-standard testing requirements


Optional Configurations:


FAQ:

1.What is a walk-in environmental chamber?

A walk-inenvironmental chamber is a large testing room that allows engineers to enter and test full-size products under controlled temperature and humidity conditions.


2.What industries use walk-in chambers?

Industries include automotive, aerospace, battery, electronics, and energy systems.


3.Can the chamber be customized?

Yes, chamber size, temperature range, humidity, and configurations can be fully customized.


4.What is the difference between walk-in and reach-in chambers?

Walk-in chambers are large enough for personnel entry, while reach-in chambers are compact and designed for smaller samples.


5.What temperature range is available?

Typically from -70°C to +150°C, with customization options available.


6. What testing standards are commonly used with walk-in environmental chambers?

Walk-in environmental chambers are commonly used for environmental reliability testing based on international standards such as IEC 60068, MIL-STD-810H, ISO 16750, and JESD22. The chamber configuration can be designed according to specific test requirements, including temperature cycling, humidity exposure, and long-duration reliability validation.


7. How do engineers select the right walk-in environmental chamber size?

Engineers should consider the product dimensions, test quantity, required airflow conditions, temperature uniformity, and future expansion needs when selecting a walk-in environmental chamber. Custom chamber designs can support large components, battery packs, vehicles, and complete systems.


8. Can walk-in environmental chambers be integrated with other testing systems?

Yes. Walk-in environmental chambers can be integrated with additional systems such as vibration testing, altitude simulation, battery safety monitoring, data acquisition systems, and customized test fixtures to create complete environmental reliability testing solutions.


Internal Linking Module

Recommended Equipment

Used for rapid temperature shock testing, suitable for reliability verification of electronic, automotive, and aerospace components.

Used for Environmental Stress Screening (ESS), it accelerates the exposure of product defects and improves product reliability upon delivery.


Related Standards (Testing Standards)

Internationally recognized environmental testing standards covering various reliability testing methods, including temperature, humidity, and vibration.

Military environmental adaptability testing standards are widely used in the verification of aerospace and military equipment.


Resources (Technical Resources)

Detailed analysis of the principles, applications, and common failure modes of temperature cycling testing.

Help engineers quickly select the appropriate type of environmental test chamber (walk-in/standard/customized).

Applications:

This walk-in environmental chamber is widely used in:


Call To Action:

Need a Custom Walk-In Environmental Chamber?

TestEQ designs and manufactures high-performance walk-in environmental chambers for automotive, aerospace, semiconductor, and research applications.

Whether you need temperature cycling, humidity testing, ESS screening, or large-scale simulation, we provide fully customized solutions based on your test requirements.


Our engineering team can help you:

  • Define test conditions and chamber configuration

  • Select the right system based on IEC / MIL / JEDEC standards

  • Optimize energy efficiency and long-term reliability

  • Provide OEM / ODM customized design support


"Request a custom walk-in environmental chamber solution todayOur engineers will design a system tailored to your testing requirements.

Related Products

Ask For A Quick Quote

We will contact you within 1 working day, please pay attention to the email with
the suffix "@test-eq.com".

We will contact you within 1 working day, please pay attention to the email with the suffix "@test-eq.com".

Company
Name*
Phone
E-Mail*
Nation
Message
By selecting the ‘I agree’ button, you consent to the processing of your personal data for marketing purposes and for the sending of commercial information by TESTEQ Company through telephone, e-mail, newsletters, text messages such as sms, chat and social networks.
I AGREE
By submitting your personal data, you declare that you have read the Privacy Policy of the website.

P.IVA: 91441900MAECQJHY37 Guangdong Test EQ Equipment Co., Ltd. | All Rights Reserved