Test EQ

All categories
PRODUCTS
Climatic Test Chamber for Temperature & Humidity Environmental Simulation

Key Advantages:

Wide temperature range from -70°C to +180°C

Humidity control range 10%RH to 98%RH

High precision environmental simulation

Stable long-duration cyclic testing capability

Programmable multi-step climate profiles

Compliant with IEC 60068, MIL-STD-810, ASTM, JEDEC

Custom chamber sizes from benchtop to walk-in systems

Key Specifications of Climatic Test Chamber:

Serial
number
Capacity ( m3 )0.2450.4081.0 
1 ModelClimatic Test ChamberETH225-40ETH225-70ETH408-40ETH408-70ETH1000-40ETH1000-70
2Internal Dimension
WxHxD (mm)
700x700x500700x800x7301000x1000x1000
3External Dimension
WxHxD (mm)
900x1680x1300900x1780x15001200x1980x1700
4   Temperature Range -40℃ to +180℃ -70℃ to +180℃ -40℃ to +180℃ -70℃ to +180℃ -40℃ to +180℃ -70℃ to +180℃
5Temperature Fluctuation≤ ± 0.5℃
6Temperature Deviation≤ ± 2.0℃
7Temperature Uniformity≤  2.0℃
8Airflow198L/Sec Cold Fusion260L/Sec Cold Fusion472L/Sec Cold Fusion
9Cooling Rate - minutes (No-Load Condition)
10 +25℃ to  -20℃301830183019
11 +25℃ to  -40℃603560326032
12 +25℃ to  -70℃
80
80
80
13 Heating Rate -  minutes (No-Load Condition)
14 -25℃ to  +150℃565656565656
15 -40℃ to  +85℃505050505050
16 -70℃ to  +85℃
60
60
60
17Humidity Range (%RH)※2 10%~98% RH
18Humidity Uniformity±1.0 % RH
19Relative Humidity Deviation ≤+2.0% ~ -3%RH (humidity>75%RH)
≤±5.0%RH (humidity≤75%RH)
20Window sizer
WxH(mm)
300x360380x520
21HeatingNoise Level
Heating/Cooling
494949494949
22Cooling656865686768
23Water Supply MethodPump Supply
24Water Tank Capacity ( L )2540
25Power  AC380V; 3 phase 5 lines ; 50/60HZ
26Current(A)Rated output power121514182532
27Power(KW)68791218
28※1 The temperature chambers model is ET-Series
※2 This indicator only applies to the humidity test chamber

Opening:

The Climatic Test Chamber is designed to simulate controlled environmental conditions including temperature, humidity, and cyclic climate changes for product reliability and durability testing.

Our systems support precise temperature and humidity control, ensuring compliance with international testing standards for accelerated environmental simulation.


Environmental Simulation Capabilities

Our climatic chambers can perform:

Why Climatic Testing Matters:

Climatic testing helps manufacturers identify:

  • Moisture-induced failures

  • Thermal expansion / contraction issues

  • Corrosion risks

  • Seal degradation

  • Material deformation

  • Early-life product failures

By simulating real environmental exposure, climatic testing improves product quality and field reliability.


Why Choose TestEQ Climatic Chambers

  • Aerospace-grade refrigeration technology

  • Industry-leading temperature/humidity stability

  • Advanced airflow uniformity design

  • Long-life compressor and refrigeration system

  • Custom engineering for demanding test requirements

  • Proven deployment in high-reliability industries


Optional Configurations:

  • Rapid temperature change upgrade

  • LN₂ / CO₂ assisted cooling

  • Low humidity package (<10%RH)

  • Multi-zone independent control

  • Remote monitoring / Ethernet / IoT

  • Explosion-proof design for battery testing


 Climatic Chamber vs Environmental Chamber:

FeatureClimatic Test ChamberEnvironmental Chamber
FocusTemperature + HumidityBroad Environmental Simulation
Typical UseClimate SimulationMulti-Stress Testing
Common IndustriesElectronics / Auto / LabAerospace / Defense / R&D

Supported Testing Standards:


FAQ:

What is a climatic test chamber?

A climatic test chamber simulates controlled temperature and humidity conditions to evaluate product reliability under environmental stress.


What is the difference between a climatic chamber and an environmental chamber?

A climatic chamber typically focuses on temperature and humidity simulation, while environmental chambers may include additional stress factors such as vibration, altitude, or salt spray.


What industries use climatic test chambers?

Industries include electronics, automotive, aerospace, defense, battery manufacturing, pharmaceuticals, and materials research.


What humidity range can a climatic chamber achieve?

Most standard chambers provide humidity control from 10%RH to 98%RH, with lower humidity options available upon request.


How do choose the right climatic chamber?

Selection depends on:

  • Product size

  • Required temperature range

  • Humidity requirements

  • Test standards

  • Ramp rate needs

Applications:

This climatic test chamber is ideal for:

  • Electronics reliability testing

  • Automotive component validation

  • Aerospace environmental simulation

  • Battery and EV testing

  • Material aging and durability studies

  • Pharmaceutical stability testing

  • Packaging and transportation simulation


Call To Action:

"Contact our engineers today for customized climatic test chamber solutions tailored to your application.

Related Products

Ask For A Quick Quote

We will contact you within 1 working day, please pay attention to the email with
the suffix "@test-eq.com".

We will contact you within 1 working day, please pay attention to the email with the suffix "@test-eq.com".

Company
Name*
Phone
E-Mail*
Nation
Message
By selecting the ‘I agree’ button, you consent to the processing of your personal data for marketing purposes and for the sending of commercial information by TESTEQ Company through telephone, e-mail, newsletters, text messages such as sms, chat and social networks.
I AGREE
By submitting your personal data, you declare that you have read the Privacy Policy of the website.

P.IVA: 91441900MAECQJHY37 Guangdong Test EQ Equipment Co., Ltd. | All Rights Reserved