1.Work room | 2.Cable Hole | 3.Sample Shelf |
The internal material is 304 stainless steel,mirror surface, rust-proof to high and low temperature and moisture corrosion;Nice ruggedness and long life |
A standard test hole, located at the left side of the work room, is provided with a sleeve nside to prevent moisture from entering the nsulation layer. Equipped with flange, the standard inner hole diameter is 50mm. Soft silicone plug seal; |
SUS304 stainless steel punching sample shelf 2pcs;Standard load of 50KGS for each layer of sample shelf The height of the shelf is adjustable and can be removed directly to facilitate the various sizes of test samples. Conducive to the air circulation |
4.Viewing Window | 5.Automatic Water Inlet | 6.Insulation |
Double layer insulating glass 8cm thick, made of tempered glass. The conductive film is located on the interior glass to prevent window frosting, built-in LED light for the work room lighting ;can clearly observe samples. The light control button is located below the controller |
Automatic control of the water intake of equipment, the customer can be directly connected to the laboratory faucet, so as to achieve automated testing; Automatic inlet diameter 1/2 inch (13.5MM); High and low water level alarm, water shortage lights and sound. Standard 2 meter drain pipe | 10cm thick polyurethane foam and insulation cotton; Better insulation performance, degradation resistance, environmental protection, noise reduction. |
7.Controller | 8.Castor | 9.Water Re-circulation |
PID programmable color touch screen controller, network connection computer Can edit 100 programs 100 segment. LIB also can preset program into the controller based on user testing requirements. The set systemlanguageis English for standard. | Install 4 castors for ease moving, and with brakes function. Caster height adjustable | Water purifier. mainly purification from water source to water tank. The filter element is suggested to be replaced once a year. Water re-circulation system that reduced water use and a series of water pipes |
High-temperature tests | Alternating temperature tests | Low-temperature tests |
IEC 60068-2-2, Test B | IEC 60068-2-14, Test Nb | IEC 60068-2-1, Test A |
ISO 16750-4, High-temperature test | ISO 16750-4, Temp. steps | ISO 16750-4, Low temperature |
ETSI EN 300019-2-4, Test Bb/Bd | ISO 16750-4, Temp. cycling | ETSI EN 300019-2-4, Test Ab/Ad |
MIL-STD-202 G, Meth. 108A | ETSI EN 300019-2-4, Test Nb | MIL-STD-810 G, Meth. 502.5 |
MIL-STD-810 G, Meth. 501.5 | MIL-STD-331 C, Test C6 | JESD22-A119 |
MIL-STD-883 J, Meth. 1008.2 | JESD22-A105C | --- |
JESD22-A103D | --- | --- |
Model | Climatic Test Chambers | THC-80(A-F) | THC-150(A-F) | THC-225(A-F) | THC-408(A-F) | THC-800(A-F) | THC-1000(A-F) |
Internal Dimension (WxHxD mm) | 400x500x400 | 500x600x500 | 600x750x500 | 600x850x800 | 1000x1000x800 | 1000x1000x1000 | |
External Dimension (WxHxD mm) | 950x1450x1000 | 1050x1550x1050 | 1150x1900x1050 | 1200x1950x1350 | 1550x2000x1350 | 1550x2000x1550 | |
Humidity Range | 20% ~98%R.H. (10%~98% R.H./5% ~98% R.H,is a special optional condition,need Dehumidifier or Dryer) |
||||||
Temperature Range | Low Temperature : (A: 25℃; B: 0℃; C: -20℃; D: -40℃; E: -60℃; F:-70℃) High Temperature : 150℃( 200℃) |
||||||
Temperature Rising/ Falling Speed Rate |
Temperature rising approx:0.1~ 3.0℃/min; Temperature falling approx:0.3-1.0℃/min |
||||||
Analytic Accuracy/ Distribution Uniformity of Temperature and Humidity |
0.1℃ ; 0.1% R.H ±1.0℃ ; ±3.0% R.H |
||||||
Control Accuracy/fluctuation of Temperature and Humidity |
±1.0℃ ; ±2.0% R.H ±0.5℃ ; ±2.0% R.H |
||||||
Optional Accessories | Inner door with operation Hole , Recorder, Water Purifier, Dehumidifier,Dryer etc | ||||||
Compressor | French "Tecumseh" Brand, Germany "Bitzer" Brand or samilar brand | ||||||
Power | AC220V; 1phase 3 lines ; 50/60HZ AC380V; 3phase 5 lines ; 50/60HZ |
||||||
Approx. Weight (Kg) | 150 | 180 | 250 | 380 | 560 | 700 |